ES3002E Dual Clamp Ground Resistance Tester – Peakforce

ES3002E Dual Clamp Ground Resistance Tester

Multifunction Ground Resistance Tester · Dual Clamp Method · Four-Wire Method · Bluetooth APP · 5-inch Color Screen

The multifunction ground resistance tester, also known as a ground resistance tester, integrates multiple measurement methods into one advanced instrument. In addition to the traditional auxiliary ground electrode measurement function, it also features a unique non-auxiliary ground electrode measurement capability. Equipped with a color display and microprocessor technology, it performs precise 4-wire, 3-wire, simple 2-wire, selective method, and dual clamp method ground resistance measurements. The large-diameter current clamp design and dual clamp measurement technology enable online measurement without driving auxiliary ground rods or isolating the grounding body from equipment. It is widely used in telecommunications, power, meteorology, machine rooms, oil fields, power distribution lines, tower transmission lines, gas stations, factory grounding grids, lightning rods, and more. The instrument is accurate, fast, simple, stable, and reliable.

2/3/4-Wire Method Dual Clamp Method Selective Method Soil Resistivity Bluetooth APP USB Data Upload 500 Data Sets Storage

Features

2/3/4-Wire Ground Resistance0.000Ω~200.00kΩ
DC Resistance0.000Ω~200.00kΩ
Selective Method Ground Resistance0.00Ω~3.000kΩ
Dual Clamp Method Ground Resistance0.00Ω~200Ω
Soil Resistivity0.00Ωm~9999kΩm
Ground Voltage0.000V~750.0V
DC Voltage0.000V~1000.0V
AC Current0.00mA~1000.0A
Test Waveform / FrequencySine Wave 128Hz

Detail Images

Product Detail Image 1 Product Detail Image 2 Product Detail Image 3 Product Detail Image 4 Product Detail Image 5 Product Detail Image 6 Product Detail Image 7 Product Detail Image 8 Product Detail Image 9 Product Detail Image 10 Product Detail Image 11 Product Detail Image 12 Product Detail Image 13

Specifications

2/3/4-Wire Ground Resistance0.000Ω~200.00kΩ Accuracy: ±1.5%rdg±70dgt Resolution: 0.001Ω
DC Resistance0.000Ω~200.00kΩ Accuracy: ±1.5%rdg±70dgt Resolution: 0.001Ω
Selective Method Ground Resistance0.00Ω~3.000kΩ Accuracy: ±2%rdg±30dgt Resolution: 0.01Ω
Dual Clamp Method Ground Resistance0.00Ω~200Ω Accuracy: ±10%rdg±10dgt Resolution: 0.01Ω
Soil Resistivity0.00Ωm~9999kΩm Accuracy: ρ=2πaR Resolution: 0.01Ωm
Ground Voltage0.000V~750.0V Accuracy: ±1.5%rdg±50dgt Resolution: 0.001V
DC Voltage0.000V~1000.0V Accuracy: ±1.5%rdg±50dgt Resolution: 0.001V
AC Current0.00mA~1000.0A Accuracy: ±2%rdg±50dgt Resolution: 0.01mA
Reference Condition23℃±5℃, below 75% rh
Power Supply11.1V lithium battery (built-in). Can continuously measure over 1000 times in AC resistance mode when fully charged.
BacklightControllable backlight, suitable for dim environments
Test Waveform / FrequencySine Wave 128Hz
Auto Power Off"APO" indicator. Automatically powers off 15 minutes after startup (default). Shutdown time can be customized.
Measurement MethodPrecision 4-wire, 3-wire measurement, simple 2-wire, selective method, dual clamp method for ground resistance measurement, average value rectification
Alarm FunctionAlarm prompt when measured value exceeds the alarm threshold
Screen Size5 inches
Electrode Spacing Range0.1m~100.0m
Measurement TimeAC current: approx. 3 times/sec. Voltage to ground: approx. 3 times/sec. Ground resistance, soil resistivity: approx. 10 sec/time
USB InterfaceHas USB interface for data reading, saving recorded data, etc.
Bluetooth APPHas remote control, real-time monitoring, data reading, and other functions
Data Storage500 data sets
Overload ProtectionMeasuring ground resistance: H-E, S-ES ports AC 280V/3 seconds
Auxiliary Ground Rods4 rods: φ10mm×200mm
Auxiliary Ground TestHas auxiliary ground resistance testing function, 0.00kΩ~200.00kΩ
Power ConsumptionScreen brightness: 190mA Max (maximum brightness) 140mA Min (minimum brightness). Measurement: 200mA Max (maximum brightness) 150mA Min (minimum brightness).
WeightInstrument: 1975g (with battery). Current clamps: 940g (2 pcs). Test leads: 1300g (including simple test leads).
Applicable Safety StandardsIEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, Pollution Degree 2); IEC61010-031; IEC61557-1 (Ground Resistance); IEC61557-5 (Soil Resistivity); JJG 366-2004 (Ground Resistance Meters); JJG 1054-2009 (Clamp Ground Resistance Meters).

Model Comparison

ModelFR3010FR3010EES3000PES3001PES3002E
2-Wire Method0.00Ω~3000Ω0.00Ω~30.00kΩ0.00Ω~20.00kΩ0.00Ω~200.00kΩ0.00Ω~200.00kΩ
3-Wire Method0.00Ω~3000Ω0.00Ω~30.00kΩ0.00Ω~20.00kΩ0.00Ω~200.00kΩ0.00Ω~200.00kΩ
4-Wire Method0.00Ω~30.00kΩ0.00Ω~200.00kΩ0.00Ω~200.00kΩ
Soil Resistivity Test0.00Ωm~9999kΩm0.00Ωm~9999kΩm0.00Ωm~9999kΩm
AC Voltage Test0.00V~600V0.00V~600V0.00V~750.0V0.00V~750.0V0.00V~750.0V
DC Voltage Test0.00V~1000V0.00V~1000V0.00V~1000V
Clamp Method AC Current Test0.0mA~1000A
Dual Clamp Method0.00Ω~100Ω
Selective Method0.00Ω~3000Ω
DC Resistance Test0.0Ω~30.00kΩ
Bluetooth Connection
Full Auto Range
Auxiliary Ground Electrode Test
Built-in Battery Charging
Full Protection Case Design
NOISE Judgment Function
USB Data Upload Function
FFT Anti-Interference Technology
Overload Protection
Battery Level Real-time Indicator
Low Battery Indicator
Auto Power Off
Backlight
Alarm Function

○ Hollow indicates not available    ● Solid indicates available

Product Accessories

Instrument1 unit (with built-in battery)
Instrument Bag1 pc
Auxiliary Ground Rods4 pcs
Current Clamps2 pcs (banana plug*1, audio plug*1)
Monitoring Software CD1 pc
USB Communication Cable1 pc
Test Leads4 pcs
Simple Test Leads2 pcs
Charger1 pc
User Manual / Warranty Card1 pc